Category
V Shape Air to Mineral Oil Dry Air Cooler for Immersion Cooling
V Shape Air to Mineral Oil Dry Air Cooler for Immersion Cooling dry air cooler Features High efficiency heat exchanger:
Basic Info.
Model NO. | D2-230 |
Form | Fixed Tube-Sheet |
Application Field | Cooling System |
Certification | RoHS, ISO, CE |
Condition | New |
Cooling Method | Direct Cooling |
Fan Motor Power | 790 |
Ambient Temperature | 40 Degree |
Product Name | V Shape Air to Mineral Oil Dry Air Cooler for Imme |
Compressor Type | Scroll |
Inlet/Outlet Pipe Diameter | 2-1/2" mm |
Feature | Dry Air Cooler |
Low-Noise High-Efficiency Fan | Running of Low Temperature Condition |
Air Pressure | 1 Bar |
Heat Transfer | 30.46kw |
Transport Package | Wooden Packing |
Specification | ISO9001: 2000 |
Trademark | Shenglin |
Origin | Shanghai, China |
HS Code | 8415909000 |
Production Capacity | 3000units/Month |
Product Description
V Shape Air to Mineral Oil Dry Air Cooler for Immersion Coolingdry air cooler Features
- High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
- Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
- We facilitate you to have a long lasting and low maintenance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.
dry air cooler Options:
1. Coil design refrigerant: water, oil, glycol.
- Multiple circuits.
- Sub-cooling circuits.
- Stainless steel or aluminum casing.
- Coated aluminum or copper fins.
- Explosion ploof motor.
- Customized fin spacing.
- adiabatic dry cooler
A wetting pad assembly is added to a dry cooler. 1. Dry Cooler with wetting pads and water distribution system 2. Uses water to obtain lower fluid temps 3. Less evaporation water usage 4. No water on coil 5. No water recirculation 6. No stagnant water 7. No blowdown 8. No aerosols (spray nozzles) 9. No drift Dry cooler with 95F ambient DB canproduce 105F LWT Add adiabatic effect to lower dry cooler EAT to 80Fand produce 85F LWT! |
adiabatic dry air cooler advantage:
1. Minimalmaintenance2. Simple visualnspection3. Maintenancefree motors4. Effective distribution pads to maximize adiabatic cooling efficiency.No wetting of coil...the coil remains clean5. Water quality may affect wetting pads (but not coils!)6. Pads are easily replaced7. Minimalwater usage
dry air cooler Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, immersion cooling bitcoin, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
Dry air cooler can use for the Single-phase/Two-phase immersion cooling systems.
dry air cooler Technical parameter:
Dry cooler D2 series parameter(fin space 2.1mm)
Type | D2-148-4x630 | D2-166-4x630 | D2-175-4x630 | D2-228-6x630 | D2-250-6x630 | D2-276-6x630 | D2-310-8x630 | D2-343-8x630 | D2-364-8x630 | D2-392-10x630 | |||
Capacity | Water | KW | 147.99 | 165.85 | 175.21 | 227.85 | 250.42 | 276.53 | 309.85 | 342.73 | 364.07 | 391.99 | |
20% Et. Glycol | KW | 142.42 | 161.57 | 170.91 | 219.09 | 244.69 | 270.22 | 301.18 | 333.55 | 354.64 | 383.3 | ||
Air flow | M3/h | 76459 | 74341 | 72134 | 114686 | 111511 | 108188 | 152911 | 148675 | 144255 | 191136 | ||
Fan | No. X φ | 2x2x630 | 2x2x630 | 2x2x630 | 2x3x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x4x630 | 2x5x630 | ||
Fan motor 400/3N/50HZ | A | 20.4 | 20.4 | 20.4 | 30.6 | 30.6 | 30.6 | 40.8 | 40.8 | 40.8 | 51.00 | ||
Sound pressure level | dB(A)10m | 64 | 64 | 64 | 66 | 66 | 66 | 67 | 67 | 67 | 68 | ||
Dimension | L | mm | 2186 | 2186 | 2186 | 3250 | 3250 | 3250 | 4250 | 4250 | 4250 | 5250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 1963 | 1963 | 1963 | 2963 | 2963 | 2963 | 3963 | 3963 | 3963 | 4963 | ||
Connections inlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Connections onlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Product weight(empty) | kg | 769 | 811 | 853 | 1134 | 1197 | 1261 | 1498 | 1589 | 1673 | 1864 |
dry air cooler Pictures:
dry air cooler package